Testing and fault-finding · Guide
Hearing loops explained: what a working loop measures, and why the sign is not enough
A hearing loop sends speech straight to a hearing aid as a magnetic field, past the echo and the noise of the room. Whether it works is a matter of four measured figures, not the blue sign by the door.
Reviewed on
Most hearing loops are judged by the sign. The ear and T symbol is on the wall, the amplifier has a green light, and nobody on the staff wears a hearing aid. So the first person to find out that the loop is silent, buzzing or patchy is the customer it was bought for, and most of them simply give up and leave.
What a hearing loop does
Many hearing aids have a telecoil: a small coil of wire that picks up a magnetic field instead of sound. The wearer switches the aid to its T (or loop) setting, and it listens to the field.
A hearing loop makes that field. A loop amplifier takes the microphone or sound system signal and drives it as a current through a cable laid round the listening area. The current produces a magnetic field that rises and falls with the speech, and every telecoil inside the area hears the talker as if they were close by. The room's echo and background noise never reach the aid, because they are not in the cable.
Loops come in a few shapes: a single cable round a room, overlapping arrays that keep the field inside the room, small loops at a counter, help point or refuge call point, and portable units for one person at short range.
Who should provide one
The Equality Act 2010 requires a service provider to take reasonable steps to provide an auxiliary aid where a disabled person would otherwise be at a substantial disadvantage (section 20(5)). For services, the duty is owed to disabled people generally (Schedule 2, paragraph 2(2)), so it is planned for in advance rather than waiting for someone to ask, and the provider cannot charge the disabled person for it (section 20(7)).
A hearing loop is one of the most common auxiliary aids for people who wear hearing aids, because the listener brings their own receiver. Whether one is reasonable in a particular reception, meeting room or auditorium is a judgement for the provider. Building guidance for new work and alterations, in England Approved Document M and BS 8300, also expects hearing enhancement where people meet and are served.
The standards, and one that has gone
Two documents matter now.
- BS EN 60118-4:2015 sets the performance a loop must deliver and how to measure it. The figures below are from it. (BSI's current edition is BS EN IEC 60118-4:2015+A1:2018; the clauses here are from the 2015 text and have not been re-read against the amendment.)
- PD IEC TR 63079:2017+A2:2020 is the code of practice for designing, installing, commissioning and maintaining hearing-loop systems. It is a Technical Report, so it advises rather than requires.
BS 7594:2011, the UK code of practice many specifications still name, was withdrawn on 7 August 2023, and BSI lists PD IEC TR 63079 in its place. If a contract still calls for BS 7594, it is worth asking which document the work will actually be checked against.
Four figures a working loop delivers
1. Field strength: 400 mA/m
The reference level is 400 mA/m, measured with a 1 kHz sine wave on a true r.m.s. meter (Clauses 3.1 and 8.2.7). With most loop amplifiers, pink noise reads about 6 dB lower on the same meter (Clause 8.2.7, Table 3), so a result means little unless it names the test signal.
2. Evenness: within ±3 dB across the listening area
Every measured point in the listening area must be within ±3 dB of that level (Clause 8.4.3), which is 283 mA/m to 566 mA/m, the figures Clause 10.4 prints. Measurements are normally taken at 1.2 m for seated listeners and 1.7 m for standing listeners (Clauses 7.1 and 8.4.2), at enough points to cover where people actually sit and stand.
Counter and refuge loops are allowed a wider ±6 dB, with at least one point reaching 400 mA/m and nowhere above +8 dB where people stand (Clauses 9.3 and 9.5). A counter loop is also measured at 1.45 m (Clause 9.4), because a poor installation can leave a dead spot at that height (Annex A, A.4).
3. Frequency response: within ±3 dB from 100 Hz to 5 kHz
The field must stay within ±3 dB of its level at 1 kHz from 100 Hz to 5 000 Hz (Clause 8.3.7), checked at least at 100 Hz, 1 kHz and 5 kHz. The standard recommends starting at 5 kHz, because that is where metal in the building shows itself (Clause 8.3.4).
4. A quiet magnetic background
Mains wiring, lighting dimmers and some equipment make magnetic noise that the telecoil hears as hum. Measured with the loop off and everything else on, A-weighted, the background should ideally be more than 47 dB below the 400 mA/m reference, and at least 32 dB below it (Clause 7.2). Below 32 dB, the standard asks for the shortfall to be reported and agreed with whoever runs the system. The loop system itself, switched on with its inputs muted, must add no more than 1 dB to that background, or stay below −47 dB in a very quiet room (Clause 10.2.7).
Metal and overspill
Two things make a loop harder than it looks on a drawing.
Metal in the structure. The loop's field induces currents in steel reinforcement, metal decks and ceiling grids, and those currents oppose it. The loss grows with frequency and with distance from the cable, (Annex F). In practice speech loses its consonants and sounds dull. This is why the 5 kHz check comes first, and why large rooms with steel floors are often covered by arrays of smaller loops.
Overspill. The field does not stop at the wall. It carries into rooms beside, above and below, where it can interfere with another loop, feed back into guitar pickups and cheap dynamic microphones, or let someone outside follow a confidential conversation (Annex I). The standard sets no numeric limit: overspill into another system's listening area should be no higher than that system's background noise target, and anything tighter is a matter for risk assessment and the contract (Clause I.3).
Keeping it working
BS EN 60118-4 recommends, in its informative annexes, that the system is checked by a trained person at regular intervals and before use, with a receiver that shows the field level (Annex E, E.5). The installer should hand over a plan of the covered area, the control settings and a way of checking the loop day to day (Annex C, C.3), and a sign near each entrance should show where the loop works and who looks after it (Annex C, C.2).
The withdrawn BS 7594:2011 set out a regime many sites still follow: a weekly listening test by a named member of staff, written in a log book, and a measured inspection by a competent person at least every 12 months. That regime is to be re-checked against PD IEC TR 63079 when our copy arrives; until then, treat it as good practice rather than a current code's recommendation.
In short
- A hearing loop delivers speech to the telecoil in a hearing aid as a magnetic field, past the room's echo and noise.
- A working loop gives 400 mA/m, within ±3 dB across the listening area, flat within ±3 dB from 100 Hz to 5 kHz, over a quiet magnetic background (BS EN 60118-4:2015).
- Metal in the building dulls the high frequencies, and the field spills into neighbouring rooms; both are design questions, not afterthoughts.
- BS 7594 has gone. PD IEC TR 63079 now advises on design and upkeep; BS EN 60118-4 still sets the figures.
Next step. If the loop in your building has not been measured since it went in, ask for the figures above at 1.2 m and 1.7 m, at 100 Hz, 1 kHz and 5 kHz, with the background noise. If something already seems wrong, start with The hearing loop isn't working. To talk it through, contactus@proaudium.com or 01273 034 630.
Questions
What field strength should a hearing loop produce?
BS EN 60118-4:2015 sets the reference at 400 mA/m, measured with a 1 kHz sine wave on a true r.m.s. meter (Clauses 3.1 and 8.2.7). Across the listening area the level must stay within ±3 dB of it (Clause 8.4.3), which is 283 mA/m to 566 mA/m, the figures Clause 10.4 prints.
At what height is a hearing loop measured?
Normally 1.2 m for seated listeners and 1.7 m for standing listeners (Clauses 7.1 and 8.4.2). A counter loop is also measured at 1.45 m (Clause 9.4), because a poor installation can leave a dead spot at that height (Annex A, A.4).
Is BS 7594 still the standard for hearing loops?
No. BS 7594:2011 was withdrawn on 7 August 2023. BSI lists PD IEC TR 63079:2017+A2:2020, a code of practice for hearing-loop systems published as a Technical Report, in its place. Performance is still measured to BS EN 60118-4.
Does a business have to provide a hearing loop?
The Equality Act 2010 requires service providers to take reasonable steps to provide an auxiliary aid where a disabled person would otherwise be at a substantial disadvantage (section 20(5)), and the duty is owed to disabled people generally, not only once someone asks (Schedule 2, paragraph 2(2)). A hearing loop is a common way to meet that for people who wear hearing aids. Whether it is reasonable in a particular place is a judgement for the provider.
Where this comes from
Every requirement this page relies on, with its clause, our explanation in our own words, and the official source to check it against. We paraphrase the standards; we do not reproduce their text.
| What the article says | Source | In our words | Official source |
|---|---|---|---|
| Reference field strength 400 mA/m; set with a 1 kHz sine wave on a true r.m.s. meter; pink noise typically reads about 6 dB lower | BS EN 60118-4:2015, Clauses 3.1, 8.2.4, 8.2.7 and Table 3 (the 2015 text; not re-read against A1:2018) | Not on our site yet | BSI: BS EN 60118-4 |
| Within ±3 dB across the listening area (283 mA/m to 566 mA/m as printed in 10.4); measured at 1.2 m seated and 1.7 m standing | Clauses 7.1, 8.4.2, 8.4.3, 10.4 | Not on our site yet | BSI: BS EN 60118-4 |
| Counter and refuge loops ±6 dB, one point at 400 mA/m or more, not above +8 dB; counters also at 1.45 m | Clauses 9.3, 9.4, 9.5; Annex A, A.4 | Not on our site yet | BSI: BS EN 60118-4 |
| Frequency response within ±3 dB of 1 kHz from 100 Hz to 5 000 Hz; 5 kHz checked first for metal loss | Clauses 8.3.4, 8.3.7 | Not on our site yet | BSI: BS EN 60118-4 |
| Background noise recommended ideally more than 47 dB, at least 32 dB, below reference; shortfall reported and agreed; system noise with inputs muted no more than 1 dB above background, or below −47 dB | Clauses 7.2, 10.2.7 | Not on our site yet | BSI: BS EN 60118-4 |
| Metal loss grows with frequency and distance from the cable; arrays of small loops counter it | Annex F (informative) | Not on our site yet | BSI: BS EN 60118-4 |
| Overspill examples; no numeric limit beyond the neighbouring system's background noise target | Annex I, I.2 and I.3 (informative) | Not on our site yet | BSI: BS EN 60118-4 |
| Regular checks by a trained person with a level-indicating receiver; handover information; sign and plan | Annex E, E.5; Annex C, C.2 and C.3 (informative) | Not on our site yet | BSI: BS EN 60118-4 |
| BS 7594:2011 withdrawn 7 August 2023; PD IEC TR 63079:2017+A2:2020 listed in its place; weekly test and 12-monthly inspection from the 2011 code | BS 7594:2011, Clauses 23 to 27; BSI catalogue entry | Not on our site yet | BSI: BS 7594 (withdrawn) |
| Reasonable steps to provide an auxiliary aid; owed to disabled people generally for services; no charge to the disabled person | Equality Act 2010, section 20(5) and 20(7); Schedule 2, paragraph 2(1) and 2(2) | Not applicable | legislation.gov.uk: Equality Act 2010, section 20 |